Zhongtong Automotive Industry Group Co., Ltd.

Part Two of the 2024 Third Quarter Emission Permit Implementation Report

2024/10/14 12:53

Part Two of the 2024 Third Quarter Emission Permit Implementation Report

2. Analysis of Actual Emission Situation and Compliance Determination

(1) Actual Emission Volume Information

Exhaust Gas

Note:

1Actual emission volume refers to the actual emission volume during the reporting period.

 

Emission Point Type

Emission Point Code and Name

Pollutants

Permitted Emission Volume (tons)

Actual Emission Volume (tons)

Remarks

Quarterly Total

7Month

8Month

9Month

Main Emission Points

DA014-Painting Workshop

Industrial Exhaust Emission Volume

/

13718345

7789802

2846523

3082020

 

Nitrogen Oxides

/

0.076536

0.02445

0.027636

0.02445

 

Sulfur Dioxide

/

0.025512

0.00815

0.009212

0.00815

 

Benzene

/

0.002138

0.000409

0.00139

0.000339

 

Toluene

/

0.003188

0.000991

0.00121

0.000987

 

Xylene

/

0.00768

0.00239

0.00311

0.00218

 

Volatile Organic Compounds

29.4

0.01795

0.00307

0.0119

0.00298

 

Particulate Matter

/

1.66e-2

5.3e-3

5.99e-3

5.3e-3

 

DA015-Drying Room 1

Industrial Exhaust Emission Volume

/

134748.08

46745.3

67746.78

20256

 

Nitrogen Oxides

/

6.52e-4

2.41e-4

2.83e-4

0.000128

 

Sulfur Dioxide

/

3.26e-4

1.2e-4

1.41e-4

0.000064

 

Benzene

/

1.76e-6

1.5e-6

1.77e-7

8e-8

 

Toluene

/

1.55e-5

5.72e-6

6.71e-6

3.04e-6

 

Xylene

/

2.48e-5

9.15e-6

1.07e-5

4.86e-6

 

Volatile Organic Compounds

/

6.36e-4

4.3e-4

1.86e-4

1.92e-5

 

Particulate Matter

/

1.47e-4

5.42e-5

6.36e-5

2.88e-5

 

DA018-Drying Room 2

Industrial Exhaust Emission Volume

/

41477.4

13382.4

11910

16185

 

Nitrogen Oxides

/

0.000301

0.000136

0.0001

0.000065

 

Sulfur Dioxide

/

1.07e-3

0.000952

0.00007

4.55e-5

 

Benzene

/

1.52e-6

1.36e-6

1e-7

6.5e-8

 

Toluene

/

1.54e-5

6.98e-6

5.13e-6

3.33e-6

 

Xylene

/

1.56e-4

1.39e-4

1.02e-5

6.63e-6

 

Volatile Organic Compounds

/

3.42e-4

2.87e-4

3.22e-5

2.25e-5

 

Particulate Matter

/

5.34e-4

0.000476

0.000035

2.28e-5

 

DA019-Drying Room 3

Industrial Exhaust Emission Volume

/

8716

1678

3741

3297

 

Nitrogen Oxides

/

0.000065

0.00002

0.00003

0.000015

 

Sulfur Dioxide

/

4.55e-5

0.000014

0.000021

1.05e-5

 

Benzene

/

2.28e-7

7e-8

1.05e-7

5.25e-8

 

Toluene

/

7.15e-6

2.2e-6

3.3e-6

1.65e-6

 

Xylene

/

9.94e-6

3.06e-6

4.59e-6

2.3e-6

 

Volatile Organic Compounds

/

3.43e-5

1.75e-5

9.39e-6

7.46e-6

 

Particulate Matter

/

1.69e-5

5.2e-6

7.8e-6

3.9e-6

 

Other Emissions (Total)

Particulate Matter

/

0

0

0

0

 

Unorganized Emissions

Unorganized

Particulate Matter

/

0

0

0

0

 

Volatile Organic Compounds (VOCs)

/

0

0

0

0

 

Total for the Plant

Industrial Exhaust Emission Volume

/

13903286.48

7851607.7

2929920.78

3121758

 

NOx

/

7.76e-2

2.48e-2

2.8e-2

0.024658

 

SO2

/

2.7e-2

9.24e-3

9.44e-3

0.00827

 

Benzene

/

2.14e-3

4.12e-4

1.39e-3

3.39e-4

 

Toluene

/

3.23e-3

1.01e-3

1.23e-3

9.95e-4

 

Xylene

/

7.87e-3

2.54e-3

3.14e-3

2.19e-3

 

VOCs

29.4

1.9e-2

3.8e-3

1.21e-2

3.03e-3

 

Particulate Matter

/

1.73e-2

5.83e-3

6.09e-3

5.35e-3

 

 

Wastewater

Note: Actual emission volume refers to the actual emission volume during the reporting period.

Emission Point Type

Emission Method

Emission Point Code and Name

Pollutants

Permitted Emission Volume (tons)

Actual Emission Volume (tons)

Remarks

Quarterly Total

7Month

8Month

9Month

                   

 

(2) Exceeding Standard Emission Volume Information

Hourly Average Report of Organized Exhaust Pollutants Exceeding Standards

Exceeding Standard Period

Production Facility Number

Emission Point Number

Exceeding Standard Pollutant Type

Actual Emission Concentration (Standardized,mg/m³)

Explanation of Exceeding Standard Reasons

2024-07-20 03:56 - 2024-07-20 04:56

MF0074

DA014

Benzene

1.28

7Month19Day19Hour30Due to heavy rain, our company's factory area experienced a complete power outage. After power was restored at20Day3o'clock, the online monitoring equipment malfunctioned, and during the period when no production was taking place and the flow was zero,3o'clock56to4o'clock42o'clock, there was a benzene exceeding standard situation, which later returned to normal.

Daily Average Report of Wastewater Pollutants Exceeding Standards

Exceeding Standard Period

Emission Point Number

Exceeding Standard Pollutant Type

Actual Emission Concentration (Standardized,mg/m³)

Explanation of Exceeding Standard Reasons

 

 

(3) Abnormal Operation Information of Pollution Control Facilities

Abnormal Operation Situation Table of Pollution Control Facilities

Fault Type

Exceeding Standard Period

(Start Period-End Period)

Faulty Facility

Fault Reason

Concentration of Each Emission Factor

(mg/m³ordB(A)

Response

Measures

Pollutant Factor

Emission Range

Exhaust Gas Control Facilities

2024-08-19 19:30-2024-09-20 05:00

TA017-Water rotation removes some pollutants, followed by zeolite wheel concentration purification,RTORegenerative Thermal Oxidation Treatment

7Month19Day19Hour30Due to heavy rain, our company's factory area experienced a complete power outage. After power was restored at20Day3o'clock, the online monitoring equipment malfunctioned, and during the period when no production was taking place and the flow was zero,3o'clock56to4o'clock42o'clock, there was a benzene exceeding standard situation, which later returned to normal.

Sulfur Dioxide

0

Production Suspension

2024-08-19 19:30-2024-09-20 05:00 Xylene

0

Production Suspension

2024-08-19 19:30-2024-09-20 05:00 Nitrogen Oxides

0

Production Suspension

2024-08-19 19:30-2024-09-20 05:00 Toluene

0

Production Suspension

2024-08-19 19:30-2024-09-20 05:00 Benzene

0

Production Suspension

2024-08-19 19:30-2024-09-20 05:00 Non-Methane Total Hydrocarbons

0

Production Suspension

2024-08-19 19:30-2024-09-20 05:00 Particulate Matter

0

Production Suspension

 

 

(4) Self-Storage/Utilization/Disposal Facility Situation

Self-Storage/Utilization/Compliance Situation Table of Disposal Facilities

Self-Storage/Utilization/Disposal Facility Number

Specific Measures to Reduce Industrial Solid Waste Generation and Promote Comprehensive Utilization

Is there excessive capacity storage?/Utilization/Disposal

Is there excessive type storage?/Utilization/Disposal

Is there excessive time storage?

Is there any situation that does not comply with the pollution control technology requirements specified in the pollutant discharge permit?

If there is more than one item selected as "Yes", please explain the specific situation and reasons.

General Solid Waste Storage - TS001

 

No

No

No

No

 

Hazardous Waste Room - TS003

 

No

No

No

No

 

Hazardous Waste Storage - TS004

 

No

No

No

No

 

Hazardous Waste Area - TS005

 

No

No

No

No

 

Waste Oil Hazardous Waste Area - TS002

 

No

No

No

No

 

 

(5) Summary

 7Month19Day19Hour30Due to heavy rain, our company's factory area experienced a complete power outage. After power was restored at20Day3o'clock, the online monitoring equipment malfunctioned, and during the period when no production was taking place and the flow was zero,3o'clock56to4o'clock42o'clock, there was a benzene exceeding standard situation, which later returned to normal.9Month15Day8Time to9Month18Day8During the Mid-Autumn Festival, production is halted. The company's operating conditions are poor, and production efficiency is low. No other abnormalities.