News Center
recommend Products
Public Announcement of the Third Quarter Execution Report for the 2023 Emission Permit
2023/12/07 14:26
Pollution Discharge Permit Implementation Report
(Quarterly Report)
Pollution Discharge Permit Number:913715001678508838001Q
Unit Name: Zhongtong Automobile Industry Group Co., Ltd.
Reporting Period: Q3 2023
Legal Representative (Actual Responsible Person): Sun Chenglong
Technical Responsible Person: Liu Qing
Landline: 0635-8518857
Mobile Phone: 15666659202
Pollution Discharge Unit Name (Seal)
Report Date: October 5, 2023
Letter of Commitment
Liaocheng City Ecological Environment Bureau:
Zhongtong Automobile Industry Group Co., Ltd. commits that all contents and data submitted in the pollution discharge permit implementation report are true and valid, and is willing to bear corresponding legal responsibilities. Our unit will consciously accept supervision from the environmental protection authorities and public oversight. If the submitted content and data do not match the actual situation, we will actively cooperate with the investigation and accept penalties according to law.
This is a commitment.
Unit Name: (Seal)
Legal Representative: (Signature)
Date:
Actual Emission Situation and Compliance Analysis
(1) Actual Emission Volume Information
Table 2-1 Exhaust Emission Volume
|
Emission Point Type |
Emission Point Code |
Emission Point Name |
Pollutants |
Actual Emission Volume (tons) |
Remarks |
|||
|
7Month |
8Month |
9Month |
Quarter Total |
|||||
|
Main Emission Points of Organized Exhaust |
DA014 |
Painting Workshop |
Xylene |
0.00689 |
0.00557 |
0.00962 |
0.02208 |
|
|
Benzene |
0.000525 |
0.000252 |
0.000265 |
0.001042 |
||||
|
Particulate Matter |
0.0055 |
0.0055 |
0.0055 |
0.0165 |
||||
|
Nitrogen Oxides |
0.025 |
0.025 |
0.025 |
0.075 |
||||
|
Toluene |
0.00323 |
0.00413 |
0.0057 |
0.01306 |
||||
|
Volatile Organic Compounds |
0.0231 |
0.0304 |
0.0242 |
0.0777 |
||||
|
Sulfur Dioxide |
0.01 |
0.01 |
0.01 |
0.03 |
||||
|
DA015 |
Drying Room 1 |
Toluene |
0.000036 |
0.000036 |
0.000036 |
0.000108 |
||
|
Sulfur Dioxide |
0.001 |
0.001 |
0.001 |
0.003 |
||||
|
Xylene |
0.000066 |
0.000066 |
0.000066 |
0.000198 |
||||
|
Nitrogen Oxides |
0.0025 |
0.0025 |
0.0025 |
0.0075 |
||||
|
Volatile Organic Compounds |
0.00192 |
0.00192 |
0.00192 |
0.00576 |
||||
|
Particulate Matter |
0.00065 |
0.00065 |
0.00065 |
0.00195 |
||||
|
Benzene |
0.000075 |
0.000075 |
0.000075 |
0.000225 |
||||
|
DA018 |
Drying Room 2 |
Sulfur Dioxide |
0.001 |
0.001 |
0.001 |
0.003 |
||
|
Nitrogen Oxides |
0.00325 |
0.00325 |
0.00325 |
0.00975 |
||||
|
Volatile Organic Compounds |
0.001335 |
0.001335 |
0.001335 |
0.004005 |
||||
|
Particulate Matter |
0.000575 |
0.000575 |
0.000575 |
0.001725 |
||||
|
Toluene |
0.000024 |
0.000024 |
0.000024 |
0.000072 |
||||
|
Benzene |
0.000059 |
0.000059 |
0.000059 |
0.000177 |
||||
|
Xylene |
0.000046 |
0.000046 |
0.000046 |
0.000138 |
||||
|
DA019 |
Drying Room 3 |
Sulfur Dioxide |
0.001 |
0.001 |
0.001 |
0.003 |
||
|
Xylene |
0.000048 |
0.000048 |
0.000048 |
0.000144 |
||||
|
Benzene |
0.000067 |
0.000067 |
0.000067 |
0.000201 |
||||
|
Volatile Organic Compounds |
0.001523 |
0.001523 |
0.001523 |
0.004569 |
||||
|
Nitrogen Oxides |
0.0035 |
0.0035 |
0.0035 |
0.0105 |
||||
|
Particulate Matter |
0.00065 |
0.00065 |
0.00065 |
0.00195 |
||||
|
Toluene |
0.000025 |
0.000025 |
0.000025 |
0.000075 |
||||
|
Others Total |
Volatile Organic Compounds |
0 |
||||||
|
Particulate Matter |
0 |
|||||||
|
Toluene |
0 |
|||||||
|
Benzene Series Compounds |
0 |
|||||||
|
Xylene |
0 |
|||||||
|
Non-Methane Total Hydrocarbons |
0 |
|||||||
|
Benzene |
0 |
|||||||
|
Total for the Plant |
SO2 |
0.013 |
0.013 |
0.013 |
0.039 |
|||
|
Particulate Matter |
0.007375 |
0.007375 |
0.007375 |
0.022125 |
||||
|
VOCs |
0.027877 |
0.035178 |
0.028978 |
0.067833 |
||||
|
NOx |
0.03425 |
0.03425 |
0.03425 |
0.10275 |
||||
Table 2-2 Wastewater Emission Volume
|
Emission Point Type |
Emission Method |
Emission Point Code |
Emission Point Name |
Pollutants |
Actual Emission Volume (tons) |
Remarks |
|||
|
7Month |
8Month |
9Month |
Quarter Total |
||||||
Note: Actual emission volume refers to the actual emission volume during the reporting period.
(2) Exceeding Standard Emission Information
Table 3-1 Hourly Average Report of Exceeding Standard Periods for Organized Exhaust Pollutants
|
Exceeding Standard Period |
Production Facility Number |
Emission Point Number |
Exceeding Standard Pollutant Type |
Actual Emission Concentration (Standardized, mg/m3) |
Explanation of Exceeding Standard Reasons
|
|
September 11, 2023 20:00 ~~ September 11, 2023 20:59 |
MF0072 |
DA014 |
Toluene |
4.08 |
Residual exhaust gas in the pipeline.
|
|
September 11, 2023 21:00 ~~ September 11, 2023 21:59 |
MF0072 |
DA014 |
Toluene |
11.5 |
Residual exhaust gas in the pipeline.
|
|
September 20, 2023 21:00 ~~ September 20, 2023 21:59 |
MF0072 |
DA014 |
Toluene |
4.88 |
Spray painting personnel violated regulations, using three spray guns simultaneously while spraying small parts.
|
|
September 22, 2023 23:00 ~~ September 22, 2023 23:59 |
MF0072 |
DA014 |
Toluene |
3.68 |
Pollution control facility malfunction, combustion chamber valve not properly closed. |
Table 3-2 Daily Average Report of Wastewater Pollutants Exceeding Standards.
|
Exceeding Standard Period |
Emission Point Number |
Exceeding Standard Pollutant Type |
Actual Emission Concentration (Standardized, mg/L) |
Explanation of Exceeding Standard Reasons |
(3) Abnormal Operation Information of Pollution Control Facilities
Table 4-1 Summary of Abnormal Conditions of Exhaust Pollution Control Facilities
|
(Exceeding Standard Period) |
Malfunctioning Facility |
Malfunction Reason |
Concentration of Each Emission Factor (mg/m3) |
Countermeasures |
|
|
Start Period - End Period |
Pollution Factor |
Emission Range |
|||
|
Exhaust Prevention and Control Facilities |
|||||
|
September 23, 2023 12:00~ October 7, 2023 12:00 |
TA017-Water rotation removes some pollutants, followed by zeolite wheel concentration purification and RTO thermal oxidation treatment. |
Planned Maintenance |
Benzene |
/ |
Shutdown and Production Stop |
|
Toluene |
/ |
||||
|
Xylene |
/ |
||||
|
Non-Methane Total Hydrocarbons |
/ |
||||
|
Sulfur Dioxide |
/ |
||||
|
Nitrogen Oxides |
/ |
||||
|
Particulate Matter |
/ |
||||
(4) Conclusion
1.Our company's drying room 3 (DA019) experienced a malfunction on August 10, requiring repairs. After sending it for repair, it was not completed until early September due to parts issues and the illness of the repair personnel. The waste gas testing company was unable to complete the gas testing on August 18 and could not upload the testing data to the monitoring platform. 2. Due to issues with the combustion chamber, the company conducted maintenance on the combustion chamber valve from 12:00 on September 23 to 12:00 on October 7, and replaced the ceramic body inside the combustion chamber.
Self-storage/utilization/disposal facility compliance status explanation form
(1) Self-storage/utilization/disposal facility compliance status explanation form
Table 5-1 Self-storage/utilization/disposal facility compliance status explanation form
|
Automatic storage/Utilization/disposal facility number |
Specific measures to reduce the generation of industrial solid waste and promote comprehensive utilization |
Is there excessive capacity for storage/utilization/disposal? |
Is there excessive variety for storage/utilization/disposal? |
Is there excessive storage duration? |
Is there any situation that does not comply with the pollution control technology requirements specified in the pollutant discharge permit? |
If there is more than one item selected as 'Yes', please explain the specific situation and reasons. |
|
General solid waste storage - TS001 |
None |
No |
No |
No |
No |
|
|
Hazardous waste room - TS003 |
None |
No |
No |
No |
No |
|
|
Hazardous waste storage - TS004 |
None |
No |
No |
No |
No |
|
|
Hazardous waste area - TS005 |
None |
No |
No |
No |
No |
|
|
Waste oil hazardous waste area - TS002 |
None |
No |
No |
No |
No |